The rung spacing on the extension section must not be less than 6 inches 15 cm nor more than 12 inches 31 cm.
Fall protection on extension ladders.
Second we are discussing what is required.
Note to paragraph d.
1910 23 b 11 requires that employers ensure workers face the ladder when climbing up or down it.
Figure d 2 slide step fixed ladder sections.
Get support for werner fall protection equipment with the werner product selection guide frequently asked questions online training and more.
Make sure they side rails are not bent or damaged.
The guardian fall protection safe t ladder extension system is designed to attach to the top of a ladder to provide a safe and easy transition from the ladder to a raised surface.
Speak with a fall protection expert today.
29 cfr 1926 1053 a 19 states that fall protection must be provided whenever the length of climb on a fixed ladder equals or exceeds 24 feet.
And if the ladder has been modified in any way do not use it.
Section 1910 28 establishes the employer s duty to provide fall protection for employees on fixed ladders and 1910 29 specifies the criteria for fall protection systems for fixed ladders.
Fixed ladders are a different story and require fall protection devices to be present when the ladder is 24 or greater in length.
It requires no tools drilling or bolting to install and is one of the most effective means of improving the safety of nearly any ladder.
Falltech ladder stanchion anchors are designed exclusively for attachment to new and existing fixed ladders for the purpose of anchoring overhead srls for fall arrest protection of single users in vertical climbing applications.
1910 23 b 12 adds a new provision requiring that employers ensure workers use at least one hand to grasp the ladder at all times when climbing up and down it.
Certainly there could be times where it is obvious that fall protection would be a good idea even though the regulation does not require it like climbing a portable ladder next to the open edge of a 15 story building.
Figure d 3 example of counterbalanced hatch cover at roof.
Ensure the safety feet are in place as well as the ladder s lanyard.
A fixed ladder is a ladder that cannot be readily moved or carried because it is an integral part of a building or structure 1926 1050 b.
Rungs cleats and steps at the base section of extension trestle ladders must not be less than 8 inches 20 cm nor more than 18 inches 46 cm apart between center lines of the rungs cleats and steps.
I need to fix some siding near the top of my 2 story house.
Are there any good fall protection options when working on an extension ladder.